Re: napco 9600 stopped communicating via serial connection

Von: Robert L Bass (sales@bassburglaralarms.com) [Profil]
Datum: 03.07.2008 13:41
Message-ID: <kvOdnc3aCP-6JvHVnZ2dnUVZ_tTinZ2d@giganews.com>
Newsgroup: alt.security.alarms
"Bob La Londe" wrote:
>
>> As to the question about common failure modes, Napco's panels don't usually
>> go bad at all.  I installed Napco systems for over 20 years and the panels
>> rarely needed service.
>
> I have only had two issues.  Not long after I started installing Napco I was
> sent a bunch of eproms for a highly reccomended upgrade on the P1632.  A few
> years later I had several P1632s with failed memory chips.  Napco replaced
> them all.

We mostly used the P3200 and P9600 on our own installations.  There were
occasional problems but nothing of any significance.  I only installed a few
P1632 systems over the years though.

--

Regards,
Robert L Bass

==============================>
Bass Home Electronics
4883 Fallcrest Circle
Sarasota · Florida · 34233
http://www.bassburglaralarms.com