Re: Ademco 20P EOLR question
Von: Crash Gordon (webmaster@siriussystems.invalid) [Profil]
Datum: 04.09.2008 06:46
Message-ID: <48bf680d$0$48220$815e3792@news.qwest.net>
Newsgroup: alt.security.alarms
Datum: 04.09.2008 06:46
Message-ID: <48bf680d$0$48220$815e3792@news.qwest.net>
Newsgroup: alt.security.alarms
on a burg zone?...im not sure that it does. -- **Crash Gordon** "Steven Vaughan" <srv@doubletrouble.net> wrote in message news:kyJvk.11595$L_.4294@flpi150.ffdc.sbc.com... > > "Jim Rojas" <jrojas@tech-man.com> wrote in message > news:d6745$48bf2f10$3641@news.teranews.com... >> If you choose to put the EOL at the panel, you might as well program the >> zone for no EOL at all. It is an option on the 20P, except for 24 hour >> type zones. >> >> Jim Rojas > > > Yabbut, programming for EOL, even if it's at the panel, will indicate > trouble on the zone with a ground fault. And it's a DIY system, so ground > faults are somewhat more likely. >[ Auf dieses Posting antworten ]